Sign In | Join Free | My himfr.com
Home > MCB Circuit Breaker >

6ka Safety Miniature Circuit Breaker 230V MCB With CE Semko Sirirm IEC60898

WENZHOU SANTUO ELECTRICAL CO.,LTD.
Contact Now
    Buy cheap 6ka Safety Miniature Circuit Breaker 230V MCB With CE Semko Sirirm IEC60898 from wholesalers
     
    Buy cheap 6ka Safety Miniature Circuit Breaker 230V MCB With CE Semko Sirirm IEC60898 from wholesalers
    • Buy cheap 6ka Safety Miniature Circuit Breaker 230V MCB With CE Semko Sirirm IEC60898 from wholesalers

    6ka Safety Miniature Circuit Breaker 230V MCB With CE Semko Sirirm IEC60898

    Ask Lasest Price
    Brand Name : SONTUNE
    Model Number : STM2-63
    Certification : CE
    Price : Negotiable
    Supply Ability : 10000PCS/DAY
    Delivery Time : 20DAYS
    • Product Details
    • Company Profile

    6ka Safety Miniature Circuit Breaker 230V MCB With CE Semko Sirirm IEC60898


    6ka Safety Miniature Circuit Breaker 2p 230V MCB With CE Semko Sirirm IEC60898


    STM5-63 eries high breaking capacity mini circuit breaker is used in AC50/60Hz, rated voltage of 230V

    3, 4 poles 400V, rated current to 63A for overload and short-circuit protection as well as for unfrequented switching under normal case.It is used extensively for industry, commercial and household.This product conform to IEC60947-3 standard.


    ModelSTM5-63 MCB
    StandardIEC60947-3
    Pole1P,2P,3P,4P
    Rated Short-circuit capacity(Icn)3KA,4.5KA,6KA
    Rated Current(In)1,2,4,6,10,16,20,25,32,40,50,63A
    Rated Voltage(Un)230/400V
    Rated Frequency50/60HZ
    Tripping curveB,C,D
    Magnetic releasesB curve: between 3and 5 In
    C curve: between 5and 10In
    D curve: between 10 and 14In
    Electro-mechanical enduranceover 6000 cycles

    General

    1. Application:For protecting cables and equipments against overload and short circuit.

    2. General rules for choosing MCB.

    1. Technical data of the network at the point considered

    The earthing systems,short-circuit current at the circuit breaker installation point,which must always be less than the breaking capacity of this device,network normal voltage.

    1. There are 3 curvve characteristics for magnetic operation:

    B curve (3-5In) protection and control of the circuits against length cables in TN and IT systems.

    C curve (5-10In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.

    D curve (10-14In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,breakdown lamps.)


    StandardIEC/EN 60898-1
    Electrical
    features
    Rated current InA1,2,4,6,10,16,20,25,32,40,50,63
    PolesP1,2,3,4
    Rated voltage UeV230/400
    Insulation voltage UiV500
    Rated frequencyHz50/60
    Rated breaking capacityA4500,6000
    Rated impulse withstand voltage(1.2/50)UimpV4000
    Dielectric test voltage at ind.Freq.for 1 minKv2
    Pollution degree2
    Thermo-magnetic release characteristicB,C,D
    Mechanical
    features
    Electrical lifet4000
    Mechanical lifet10000
    Protection degreeIP20
    Reference temperature for setting
    of thermal element
    30
    Ambient temperature
    (with daily average ≤35℃)
    -5~+40(Special application please refer to
    temperature compensation correction)
    Storage temperature-25~+70
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cablemm225
    AWG18-3
    Therminal size top/bottom for busbarmm225
    AWG18-3
    Tightening torqueN*m2
    In-lbs18
    Mountingon DIN rail EN 60715(35mm)by means of fast clip device
    ConnectionFrom top and bottom