Sign In | Join Free | My himfr.com
Home > RCCB Circuit Breaker >

Using recharge station or solar device B model RCCB 2P 4 Pole Residual Current Circuit Breaker

WENZHOU SANTUO ELECTRICAL CO.,LTD.
Contact Now
    Buy cheap Using recharge station or solar device B model RCCB 2P 4 Pole Residual Current Circuit Breaker from wholesalers
     
    Buy cheap Using recharge station or solar device B model RCCB 2P 4 Pole Residual Current Circuit Breaker from wholesalers
    • Buy cheap Using recharge station or solar device B model RCCB 2P 4 Pole Residual Current Circuit Breaker from wholesalers
    • Buy cheap Using recharge station or solar device B model RCCB 2P 4 Pole Residual Current Circuit Breaker from wholesalers

    Using recharge station or solar device B model RCCB 2P 4 Pole Residual Current Circuit Breaker

    Ask Lasest Price
    Brand Name : SONTUOEC ,WZSTEC
    Model Number : STID-B
    Certification : IEC/EN 61008-1,IEC/EN 62423
    Price : 62.5-75(USD)
    Supply Ability : 1000PCS/DAY
    Delivery Time : 20DAYS
    • Product Details
    • Company Profile

    Using recharge station or solar device B model RCCB 2P 4 Pole Residual Current Circuit Breaker

    B model RCCB 2P 4 Pole Residual Current Circuit Breaker using recharge station or solar device


    STID-B RCCB B model is worked on type A and in additon for smooth DC residual currents, residual DC currents that may result fromrectifying circuits and high frequency AC residual currents.Itprotects in the event ofcontunuous fault current on three phase networks.Itusually is used in the field of Recharging Station,MedicalApparatus and Instruments, Controllers and Variable Speed Drives, Batter Chargesand Inverters(DC)..STID-B complys with IEC/EN61008 and IEC/EN62423 standard.



    General
    1. Application:For protecting cables and equipments against overload and short circuit.
    2. General rules for choosing RCCB.

    1. Technical data of the network at the point considered

    The earthing systems,short-circuit current at the circuit breaker installation point,which must always be less than the breaking capacity of this device,network normal voltage.

    1. There are 3 curvve characteristics for magnetic operation:

    B curve (3-5In) protection and control of the circuits against length cables in TN and IT systems.
    C curve (5-10In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
    D curve (10-14In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,breakdown lamps.)


    ModelSTID-B
    StandardIEC/EN 61008-1,IEC/EN 62423
    Poles1P+N,3P+N
    Rated Circuit In(Rci)25A,40A,63A
    Rated Short-circuit capacity(Icn)6KA
    Rated Voltage(Un)230(240)/400(415)V
    Rated Frequency50/60HZ
    Tripping curveB,C,D
    Magnetic releasesB curve: between 3and 5 In
    C curve: between 5and 10In
    D curve: between 10 and 14In
    Electro-mechanical enduranceover 10000 cycles