Sign In | Join Free | My himfr.com
Home > ELCB Circuit Breaker >

2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

WENZHOU SANTUO ELECTRICAL CO.,LTD.
Contact Now
    Buy cheap 2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker from wholesalers
     
    Buy cheap 2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker from wholesalers
    • Buy cheap 2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker from wholesalers

    2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

    Ask Lasest Price
    Brand Name : SONTUNE
    Model Number : STG
    Certification : CE
    Price : Negotiable
    Supply Ability : 2000pcs/day
    • Product Details
    • Company Profile

    2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

    STG(Pg)Series 2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker


    GENERAL


    An Earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations with high Earth impedance to prevent shock. It detects small stray voltages on the metal enclosures of electrical equipment, and interrupts the circuit if a dangerous voltage is detected. Once widely used, more recent installations instead use Residual Current Circuit Breakers which instead detect leakage current directly.


    Specification:


    TypeSTG230STG420
    Rated Current(A)10A,15A,20A,25A,32A,40A,50A,60A10A,15A,20A,25A,32A,40A,50A,60A
    Pole Number2Pole4Pole
    Leakage acting current(mA)300mA,500mA300mA ,500mA
    Range of break-off0.5~1.0X IΔn0.5~1.0X IΔn
    Rated Voltage(V)220V-250VAC240V/415VAC
    Tripping time100ms100mS
    Life100000 times100000 times
    Ambient Temperature-5°C ~ +55 °C-5°C ~ +55 °C

    Voltage-operated (ELCB)


    Voltage ELCBs have been in widespread use since then, and many are still in operation but are no longer installed in new construction. A voltage-operated ELCB detects a rise in potential between the protected interconnected metalwork (equipment frames, conduits, enclosures) and a distant isolated Earth reference electrode. They operate at a detected potential of around 50 volts to open a main breaker and isolate the supply from the protected premises.


    A voltage-operated ELCB has a second terminal for connecting to the remote reference Earth connection.


    The Earth circuit is modified when an ELCB is used; the connection to the Earth rod is passed through the ELCB by connecting to its two Earth terminals. One terminal goes to the installation Earth CPC (circuit protective conductor, aka Earth wire), and the other to the Earth rod (or sometimes other type of Earth connection).

    Quality 2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker for sale
    Inquiry Cart 0